Error 711: When attempting to start the Routing and Remote Access Service, you may receive "The Routing and Remote Access service terminated with service-specific error 711" and Event ID: 7024  in the System Event log of the server shows. This behavior may occur because the Routing and Remote Access Service is unable to start if the Remote Access Connection Manager service, Remote Access Auto Connection Manager, and the Telephony service are disabled.

RESOLUTION: to resolve this behavior, you must use the Services Administrative tool to set the Startup Type of all the Remote Access Connection Manager service, Remote Access Auto Connection Manager, and the Telephony service to Manual.. After you have made these settings, you can restart the Routing and Remote Access Service.